| Plasma phosphorylated tau (p-tau217) | Blood plasma; assay measures a phosphorylated tau species associated with Alzheimer’s-related changes. | Can help identify Alzheimer’s pathology in the appropriate clinical context. It is not, by itself, a complete diagnosis of dementia or its cause. | Assess sensitivity and specificity against an appropriate reference standard, such as amyloid PET or validated CSF biomarkers. Review results by intended-use population and decision threshold. | Request independent, prospective studies; prespecified cut-offs; analytical precision; interference testing; and performance data across relevant age, disease-stage, and comorbidity groups. | Potentially useful as part of a specialist-led diagnostic pathway. Interpretation should consider symptoms, examination, and other investigations; a positive result may require confirmation under local guidance. |
| Other plasma p-tau assays (for example, p-tau181 or p-tau231) | Blood plasma; measures a different phosphorylated tau target from p-tau217. | May provide evidence associated with Alzheimer’s pathology. Different p-tau targets and assay methods are not automatically interchangeable. | Evaluate each assay separately against the reference method and intended clinical question. Check sensitivity, specificity, confidence intervals, and performance near the clinical cut-off. | Confirm the exact analyte, assay platform, calibration, sample handling requirements, reproducibility, and validation in the population where the test will be used. | Use only for the purpose supported by the test’s evidence and applicable local authorization or guidelines. A biomarker result does not replace clinical assessment. |
| Plasma amyloid-beta ratio (Aβ42/Aβ40) | Blood plasma; measures the ratio of two amyloid-beta peptides. | Can contribute information about amyloid-related pathology; results depend on the assay and its validated threshold. | Check agreement with amyloid PET or CSF reference results, as well as sensitivity, specificity, and the rate of indeterminate results. | Review analytical sensitivity, precision, lot-to-lot consistency, pre-analytical requirements, and external validation. Ask whether cut-offs were established independently of the evaluation cohort. | Do not treat an isolated ratio as proof of clinical Alzheimer’s disease. Use within a defined pathway and interpret alongside symptoms and other findings. |
| CSF Aβ42/Aβ40 with phosphorylated tau | Cerebrospinal fluid collected by lumbar puncture; commonly includes amyloid-beta and tau biomarkers. | Provides information about amyloid and tau changes associated with Alzheimer’s pathology. | Assess performance using validated reference methods, established interpretive criteria, and clinically relevant patient groups. Review inconclusive-result rates as well as overall agreement. | Verify laboratory accreditation, assay-specific cut-offs, quality-control procedures, sample tube and handling instructions, and external quality assessment participation. | Invasive sampling requires trained staff and informed consent. Results should be interpreted with the clinical presentation and the laboratory’s validated reference ranges. |
| Amyloid PET imaging | Imaging after administration of an amyloid-targeting radiotracer; interpreted using validated visual or quantitative methods. | Assesses amyloid plaque burden in the brain. It does not independently establish that amyloid is the cause of a person’s symptoms. | Review reader agreement, image-quality procedures, interpretation criteria, and performance in the population for which imaging is proposed. | Confirm access to qualified readers, tracer and scanner protocols, radiation-safety procedures, and documented quality assurance. | May be used as a confirmatory test when clinically appropriate and available. Consider radiation exposure, cost, access, and local guidelines. |
| Neurofilament light (NfL), blood or CSF | Blood or cerebrospinal fluid; measures a marker of neuronal injury. | Can indicate neuroaxonal injury but is not specific to Alzheimer’s disease; levels may be affected by other neurological conditions and age. | Evaluate whether the study tests detection of neuronal injury or Alzheimer’s pathology. Do not interpret non-specific injury-marker performance as Alzheimer’s diagnostic accuracy. | Review age-adjusted reference data, assay precision, clinical confounders, and evidence for the specific intended use. | May support assessment or monitoring in selected contexts, but should not be used alone to identify Alzheimer’s pathology. |
| Clinical and analytical validation — applies to every test | Review the complete test system: specimen, collection, transport, laboratory method, reporting, and intended user. | Establishes whether the test measures its target reliably and whether its results are useful for the proposed clinical decision. | Request sensitivity, specificity, confidence intervals, positive and negative predictive values at relevant disease prevalence, and comparison with an appropriate reference standard. Check handling of borderline results. | Look for independent, prospective, multi-site validation; clear inclusion and exclusion criteria; prespecified cut-offs; reproducibility; interference studies; and transparent limitations. | Confirm intended-use claims, applicable regulatory status in the destination market, laboratory requirements, reporting language, turnaround time, and a defined pathway for follow-up or confirmation. |