| Meaning of “≥98%” | Confirm whether the figure refers to HPLC area percentage, assay by weight, or another calculation. | A written specification defining the test, calculation, reporting basis, and acceptance limit. | “≥98% HPLC” alone is ambiguous. HPLC area percentage describes the relative detector response of measured peaks; it is not automatically equivalent to 98% w/w content. |
| Test method | Review the method’s chromatographic conditions, sample preparation, calculation, and suitability for dihydroberberine. | The test method or a sufficiently detailed method summary, including the detector and column conditions. | A defined, reproducible method makes the result more assessable. The term “HPLC” by itself does not specify a complete analytical procedure. |
| Batch-specific result | Check that the reported result applies to the exact production lot offered for sale. | A dated, lot-specific certificate of analysis (COA) with the sample or batch identifier and test result. | A generic specification or sample COA does not establish the result for a different lot. |
| Identity confirmation | Verify that the tested material is identified as dihydroberberine, not merely as a high-purity chromatographic peak. | An identity test and its result, such as a documented spectroscopic or other suitable analytical comparison. | Purity and identity are separate questions; a purity percentage alone does not establish chemical identity. |
| Reference standard | Ask what reference material, if any, was used for identification or quantitative assay, and how it was qualified. | Reference-standard identity, source or qualification details, and the procedure used for comparison. | Reference-standard information helps assess traceability. A peak-area normalization result may not use a quantitative reference standard. |
| Chromatographic record | Check whether the chromatogram supports the reported result and shows the relevant sample peaks. | A sample chromatogram with peak labels and integration, plus a blank or system-suitability record when available. | Chromatograms aid review of peak separation and integration. A chromatogram alone does not prove that the method is validated or that the result is a mass assay. |
| Method validation or verification | Ask whether the method has been validated or verified for its intended use, including relevant performance characteristics. | A validation or verification summary addressing applicable characteristics such as specificity, precision, and range. | The supporting evidence should be appropriate to the method and intended claim; do not infer validation from an assay number alone. |
| Moisture and reporting basis | Determine whether the result is reported as-is, on a dried basis, or on another defined basis. | The COA’s reporting basis and, where relevant, separate moisture or loss-on-drying result. | Different reporting bases can produce different percentages. The basis must be clear before comparing results. |
| Independent confirmation | Consider testing a representative sample at an independent laboratory using an agreed method. | A third-party report identifying the sample, method, result, and reporting basis. | Independent testing can provide additional evidence for a specific sample; it does not automatically guarantee future batches. |
| Supplier conclusion | Evaluate whether the supplier provides consistent, traceable documentation for the requested lot. | A matching specification, lot-specific COA, analytical method information, and supporting records where appropriate. | A “≥98%” claim is verifiable only when its meaning, method, sample, and reporting basis are sufficiently defined and supported. This table sets out verification checks; it does not report test results for any supplier or batch. |